Accession Number AD-A176 937/1
Title Repair, Evaluation, Maintenance, and Rehabilitation Research Program. Repair of Waterstop Failures: Case Histories.
Publication Date Nov 1986
Media Count 244p
Personal Author J. E. McDonald
Abstract Nearly every concrete structure has joints that must be sealed to ensure its integrity and serviceability. This is particularly true for for monolith joints in hydraulic structures such as concrete dams and navigation locks. Embedded waterstops are genera ...
Keywords Concrete
Dams
Failure(Mechanics)
History
Hydraulic equipment
Joints
Leakage(Fluid)
Locks(Waterways)
Maintenance
Materials
Navigation
Overload
Rehabilitation
Repair
Seals(Stoppers)
Structures
Water


 
Source Agency Non Paid ADAS
NTIS Subject Category 50B - Civil Engineering
50C - Construction Equipment, Materials, & Supplies
Corporate Author Army Engineer Waterways Experiment Station, Vicksburg, MS. Structures Lab.
Document Type Technical report
Title Note Final technical rept.
NTIS Issue Number 8711
Contract Number N/A

Science and Technology Highlights

See a sampling of the latest scientific, technical and engineering information from NTIS in the NTIS Technical Reports Newsletter