Loss-of-coolant accident experiment at the AVR gas-cooled reactor.
Oak Ridge National Lab., TN.

ProductType: Conference proceedings
NTIS Order Number: DE90012732

 
Media Count: N/A
Date: 1990
Author: K. Krueger J. Cleveland

A landmark safety test has been conducted at the AVR-reactor, a high-temperature gas-cooled reactor (HTGR) in the Federal Republic of Germany owned by the Arbeitsgemeinschaft Versuchsreaktor, AVR in Juelich. The 46-MW(t), 15-MW(e) AVR reactor was subjecte ...